Scilab Function ffilt - coefficients of FIR low-pass
Calling Sequence
- [x]=ffilt(ft,n,fl,fh)
Parameters
- ft
: filter type where ft can take the values
- "lp"
: for low-pass filter
- "hp"
: for high-pass filter
- "bp"
: for band-pass filter
- "sb"
: for stop-band filter
- n
: integer (number of filter samples desired)
- fl
: real (low frequency cut-off)
- fh
: real (high frequency cut-off)
- x
: vector of filter coefficients
Description
Get n coefficients of a FIR low-pass,
high-pass, band-pass, or stop-band filter.
For low and high-pass filters one cut-off
frequency must be specified whose value is
given in fl. For band-pass and stop-band
filters two cut-off frequencies must be
specified for which the lower value is in
fl and the higher value is in fh
Author